Sedimentation

Plate Settler Spacing - Filter Foam, Summer 2009

Rachel Beth Phillipson

Abstract:

At the plants in Honduras, the head loss through the lamella plates is much less than the head loss from the water flowing through the inlet ports. Because of this, the flow throughout the plate settlers is uniformly distributed. To even out these flows, a geotextile foam is placed on top of the plate settler to create the same head loss through the lamella plates and the water flowing through the inlet ports.

Plate Settler Spacing - Alum Doses, Summer 2009

Rachel Beth Phillipson

Robustness of our plate settler design is defined as the ability of the plate settlers to produce 1 NTU water over a variety of non-ideal conditions. One set of non-ideal conditions was building a floc blanket with underdoses and overdoses of alum to measure performance through effluent turbidity from the tube settler.

Plate Settler Spacing - Experiments with Velocity Gradients, Fall 2009

Alexander Campbell Duncan, Rachel Beth Philipson

Abstract:

The Plate Settler Spacing team is currently investigating the Floc Roll-Up Phenomenon in the tube settler. By developing a velocity gradient model, we hope to both analytically and experimentally determine the critical velocity floc particles experience when they begin to roll up the settler tube and into the effluent rather than settling back down the tube and into the floc blanket. The critical velocity is determined using a force balance for a floc particle. In addition to determining this critical velocity, we hope to understand how properties of the flocs themselves affect floc roll-up.

Plate Settler Spacing - Experiments with Saturated Water, Fall 2009

Christine Lauren Catudal, Matthew William Hurst

This experiment explored the impact of water supersaturated with respect to atmospheric pressure on floc blanket formation and performance. This experiment involved collaboration with the Floating Floc Research Team, who supplied the saturated water that served as the influent water to the process.

Plate Settler Spacing - Velocity Gradients, Spring 2010

Tanya Suntikul Cabrito

Stepping from previous research with velocity gradients, this experiment seeks to uncouple their effects on tube settler performance deterioration from those of the capture velocity. In the team's last experiments (detailed in Exploring the Coupled Effects of Capture Velocity on Settler Performance), it was hypothesized that maintaining a constant length to diameter ratio in tube settlers would minimize the effects of the capture velocity on performance.

Plate Settler Spacing, Fall 2010

Tanya Cabrito, Jae Lim, Cosme Somogyi

Abstract:

The goal of the Plate Settler Spacing Team (PSS) is to study the lamellar sedimentation process in plate settlers and the efficiency of the removal of flocculated particles and establish improved guidelines for plate settler spacing. The traditional guidelines for plate settlers state that the spacing between plates cannot be less than 5 cm and little to no justification can be found for this. The team's results show that performance in accordance with the US drinking water standard of 0.3 NTU can be achieved with spacings smaller than 5 cm. Also, all but one of the experiments meet the World Health Organization standard of 5 NTU. For AguaClara plants, having smaller spacings between plate settlers allow the sedimentation tank to be shallower and therefore cheaper.  Smaller spacings also allow for increased head loss across the plate settlers. This would help even out the distribution of flow in AC plants and allow the plate settler system to function at its design capture velocity of 0.12 mm/s throughout. The team had finished velocity gradient experiments with a clay aluminum hydroxide system; however, a recently discovered mistake in documentation caused the team to reassess the data collected this semester and more tube trials must be run. Due to this error, the team changed the capture velocity for the velocity gradient from 0.12 mm/s to 0.10 mm/s.  The major tasks completed by the Fall 2010 PSS team are catching a documentation error that happened at the end of Spring 2010, studying the effects of high velocity gradients and floc rollup on plate settler performance, developing a macro that significantly facilitates data analysis and a plate settler dynamics model that may better shed light into processes governing plate settler performance.

Chemical Dose Controller Development, Fall 2010

Eva Luna, Drew Hart, Larry Lin, Roy Guarecuco

Abstract

The Fall 2010 Chemical Dose Controller team has focused on designing the dose controller to be visually accessible, more aesthetically attractive, and robust. The apparatus will be mounted on a plywood board secured to the plant wall. The team has begun construction on a prototype for the design. In this report we have documented the design process and all of the component parts used in the prototype.

Sedimentation Tank Hydraulics, Spring 2011

Yiwen Ng, Anna Lee, Tiffany Tsang

Abstract

Previously our team worked on designing a scaled down model of sedimentation tank in order to study floc blanket formation in 3D models. However, we decided that it would be more effective to continue the study with the existing 2D sedimentation tank. Using this tank our first objective was to determine the minimum angle of repose. We have hypothesized that for an insert angle below 60 degree that a floc blanket would not form. The slope of the insert would not be sufficient for the flocs to be transported to the jet, thus the flocs would accumulate on the incline. However, even when we decreased our angle of repose to 30 degrees, we were successful in forming the floc blanket.

Plate Settler Spacing, Spring 2011

The Effect of Floc Roll-up on Clay-Aluminum Hydroxide Flocs

Matt Hurst, Monroe Weber-Shirk*, Tanya Cabrito, Cosme Somogyi, Michael Adelman, Zachary Romero, Richard Pampuro, Rachel Phillipson, Sarah Long, Colette Kopon, Ying Zhang, Ashleigh Sujin Choi, Adela Kuzmiakova, Jae Lim, Alexander Duncan, Christine Catudal, Elizabeth Tutunjian, Ling Cheung, Kelly Kress, Tiara Marshall, and Leonard W. Lion

Abstract:

Inclined plate and tube settlers are commonly used to create compact sedimentation tanks. Conventional design guidelines are based on obtaining a desired sedimentation design capture velocity. Theoretically, this capture velocity can still be achieved while greatly reducing conventional plate spacing or tube diameter. The greatest concern with small plate spacing is the danger of settling sludge being swept out with the finished water. This research presents the basis of this failure mechanism as high velocity gradients present at small tube settler diameters and small plate settler spacings.

Plate Settler Capture Velocity, Fall 2011

Ruonan Zhang, Xiaocan Sun, Yizhao Du

Abstract:

Through lab research we seek to understand the different influence of coagulant type, capture velocity, coagulant dose and raw water turbidity on the performance of the plate settler in AguaClara plants. We are using a tube settler to simulate those plate settlers in the full-scale plants. Through various changes in operating conditions, we expect to determine the best parameters, and this is of great significance in real practice. After that, we are going to pick out some of the best conditions and repeat the experiments with natural organics in order to see how humic acids affect overall performance.

Sedimentation Tank Hydraulics, Summer 2011

Elana Liskovich, Mahina Wang, Jill Freeman, Yiwen Ng

Abstract:

A floc blanket is a dense fluidized blanket of flocs that helps to reduce effluent turbidity in the sedimentation tank by trapping other flocs. The geometry of the sedimentation tank is crucial in determining the extent of floc resuspension by the jet and hence floc blanket formation. To improve tank bottom geometry, nine experiments were conducted, each testing a different tank bottom geometry. The experiments were run in a 1/2 inch wide tank to model a thin slice of the full scale sedimentation tank. The geometry that resulted in the least sludge accumulation and therefore best floc resuspension was two 60 degree inserts leading to a semicircular trench 10 cm in diameter. We also provided initial designs and calculations for a floc weir to maintain the height of the floc blanket. A preliminary experiment was also conducted to evaluate the feasibility of our initial floc weir design.

Sedimentation Tank Hydraulics, Fall 2011

Jill Freeman, Mahina Wang, Saied Khan, Matthew Hurst

Abstract:

A floc blanket is a dense, fluidized bed of particles that forms in the sedimentation tank and helps to reduce effluent turbidity by trapping small flocs and reduces clean water waste through less frequent draining of the sedimentation tank. Floc resuspension is necessary for floc blanket formation so that flocs are recirculated through the tank instead of settling on the tank bottom as sludge. Research was conducted to examine mechanisms for floc resuspension. Parameters important for floc resuspension include energy of the jet stream on its upward flow path, position of the jet as it interacts with solids, and hydrodynamic pressure of the jet compared to hydrostatic pressure of the returning solids. Several geometries were tested with red dye and fully built floc blankets to observe the jet path and velocity profile around the bottom geometry. Best results are achieved through geometries that preserve jet momentum, especially through splitting the jet flow, and geometries that maintain a high jet velocity when contacting solids. Later, quantitative measurements were taken to determine floc blanket performance for various bottom geometries.

Sedimentation Tank Hydraulics, Spring 2012

Jill Freeman, Mahina Wang, Matthew Hurst, Saied Khan, Yiwen Ng

Abstract:

A floc blanket is a dense, fluidized bed of particles that forms in the sedimentation tank. It helps to reduce effluent turbidity by trapping small flocs and reduces clean water waste through less frequent draining of the sedimentation tank. Floc resuspension is necessary for floc blanket formation so that flocs are recirculated through the tank instead of settling on the tank bottom as sludge. Research was conducted to examine the effectiveness of the retrofitted Marcala sedimentation tank. At high influent turbidities, a steady floc blanket was obtained, but performance was slightly compromised when the influent turbidity was lowered to simulate Marcala conditions during the dry season. A floc blanket visibly formed with an influent turbidity of 5 NTU after about 1 week but “seeding” the tank with coagulated flocs will minimize floc blanket formation time. Images were also acquired for hindered sedimentation velocities of 0.6 mm/s, 1.2 mm/s, and 1.6 mm/s and analyzed with a floc-water interface program using a region of interest to better understand hydraulic processes within a floc blanket. Complete settling curves from this data confirmed wall effects significantly affect settling velocity. A floc hopper proved to be effective at controlling the height of the floc blanket when the accumulated flocs were drained at an adequately high flow rate. A lower alum dose of about 39 mg/L for an influent turbidity of 100NTU resulted in a less sticky sludge that could be more easily drained from the hopper.

Sedimentation Tank Hydraulics, Summer 2012

Danielle Feng, Jill Freeman, Cari Gandy

Abstract:

In the sedimentation tank of an AguaClara water treatment plant, water flows through the inlet manifold with vertical diffusers that channel the water into the bottom of the tank as a line source. As water exits the vertical diffusers, a semi circular half pipe jet reverser directs the water upward to resuspend flocs to form a floc blanket, or a dense, fluidized bed of particles, in the sedimentation tank below the plate settlers. A floc blanket increases the particle removal efficiency of the sedimentation tank by capturing smaller flocs that would otherwise escape through lamellar sedimentation. A floc blanket also leads to less clean water waste because without a floc blanket, sludge builds up at the bottom of the tank and will require constant draining. While current plant designs use a 0.5” radius jet reverser and centered jet placement, other jet reverser sizes and jet placements were explored to increase floc resuspension and floc blanket stability. A 1.5” radius reverser with asymmetric jet placement was found to be the optimal design for floc resuspension. Floc blanket stability in relation to coagulent dose was also explored, and optimal alum doses for several influent turbidities were determined.

Sedimentation Tank Hydraulics, Fall 2012

Frances Ciolino, Hongyi Guo, Ethan Yen

Abstract:

The sedimentation tank hydraulics team this semester focused on optimizing the floc hopper. Our main goal was to learn more about the floc hopper geometry and reasons for floc blanket failure. We started the semester by looking at the vertical sedimentation velocity. This velocity is controlled by the flow into the tank and affects how fast the particles settle. If this velocity is too high or too low, the sedimentation tank will not form a proper floc blanket.

We also looked into how the plan view area of the floc hopper would effect the floc blanket formation and performance. Changing the size of the floc hopper effects how much of the area allows for up-flow of the water and how much captures the flocs. In our current experiments we are trying different sizes at different wasting rates. We are looking for a size and rate that keeps the plant running efficiently, meaning the least amount of water wasted while keeping the water leaving the plant clean.

One of the ideas we are working on is continuous wasting of the flocs. The idea behind this is to allow for constant removal of flocs instead of collecting the flocs and then manually opening a valve to let them leave the tank. When the wasting rate is optimal, the flocs will be allowed to compact before they are removed so that the least amount of water is lost in the process. Our last experiment looked at finding the proper wasting rate where the rate of particles flowing into the floc hopper is the same as the rate at which the particles are being removed.

aguaclara+logo.png

High Rate Sedimentation - Fall 2016

Ziwei (Vanessa) Qi, Aimee Owens, Ruizhe He

Abstract:

The Fall 2016 High Rate Sedimentation team investigated the effect of high upflow rates on maintaining a dense floc blanket and functional plate settlers. The team built a small-scale flocculator and tube model of the sedimentation tank in order to simplify the many experiment variation configurations.To analyze variables that effect effluent turbidity at an up- flow velocity of 3 mm/s, which is roughly triple the standard AguaClara rate. Experiment 1 varied length of the tube settlers, Experiment 2 varied length of the floc blanket, and Experiment 3 attempted to increase the density of the floc blanket by adding mass. Experiments have verified that longer tube settlers and longer floc blankets improve sedimentation tank performance.

flocblanket.PNG

Sand Source and Testing - Fall 2013

Rebecca Schneider and Meghan Furton

Abstract:

The Sand Source and Test Methods sub-team is new to AguaClara this semester. Our main sources of research come from the known SRSF sand constraints, which dictate that no sand should be able to slide through the 0.2 mm slots in the PVC pipe, the sand should be hard and not prone to dissolution in acid, the backwash velocity required to expand the filter bed by 30% should be very close to 11 mm/s, and the sand bed must not have significant stratification after backwash. In addition to the constraints provided by the SRSF, the filter sand used must also satisfy American Water Works Association guidelines (AWWA). We are using American Water Works Association (AWWA) media constrains along with the American Society for Testing and Materials guidelines (ASTM International) to compile a series of test methods for filter sand. We intend to determine which of these constraints apply to the SRSF design. Furthermore, progress towards local sand acquisition is varied between the sites in India and Honduras as of September 2013. In India, sand is currently taken from the Barakar river and the only modifications made are sieving it for correct size on site, using two large rectangular mesh sheets that are shaken by two people. The two sieve sizes currently in use are No. 60 and 30, which correspond to particle sizes of 0.25 mm and 0.5mm respectively. There is also potential access to laboratories in the Universities and NGOs nearby. In Honduras, on the other hand, there is not an established sand mine industry and sand will likely be taken from river beds near the site. Transporting this sand from the river to the site is easy, but testing will be done in the apartments without the use of laboratory equipment that is difficult to transport.

aguaclara.png

Sed Tank Temperature Gradients, Spring 2014

Dhaval Mehta, Hui Zhi, Surya Kumar

Abstract

AguaClara is an engineering program based at Cornell University that develops sustainable  water treatment technology with current applications in developing countries. In Honduras,  one  of  the  countries  with  AguaClara  technologies,  the  treatment  plant  at  San  Nicolas  experiences raw water with a temperature gradient of around 1°C/hr during warming and  cooling  portions  of a  day. These gradients  are  primarily  caused  due  to  the  approximately  15km of piping that brings raw water to the plant, much of which is exposed to the sun.  Agua  Clara  plants  use  sedimentation  tanks  with  floc  blankets  and  plate  settlers.  The  temperature gradient  during warming  periods  causes a  circulation  current  to  form in  the  vertical Gflow sedimentation  tank, due  to  the effect of continually warmer water displacing  colder water. This current in the tank at San Nicolas causes flocs to aggregate on one side of  the  tank and rise up  to  the  top with  the hotter, less dense water; hence  the effluent water  leaving the tank is not sufficiently clean. Our experiment is motivated by this problem, with  the  goal  of  studying  the  problem’s  origins  and  providing  initial  research  towards  its  solution

image34.PNG

Convection Flow in Plate Settlers, Spring 2014

Eric Grohn

Abstract

The AguaClara project team develops a simple, low-cost water purification plant for developing global communities. One part of the AguaClara plant is a sedimentation tank. During this stage of the purification, large coagulated contaminant particles (”flocs”) collect and settle out of the water, leaving it cleaner than before. Recently, one problem has been noticed with the current design of the AguaClara sedimentation tank. If the water entering the tank is warmer than the water already within, the tank doesn’t perform as well as it should. The suspected reason for this is that the warm buoyant water rises rapidly to the top of the tank, taking the flocs with it, at a velocity that is too great for the tank to function correctly. The top of the tank consists of an array of angled closely packed parallel plates called plate settlers. My project here is to determine the flow pattern for a convective flow through the plate settlers, with the hope that this will provide a clearer picture of the poor sedimentation tank performance. A 2d analytical solution is determined for the flow velocity between two angled parallel plates when the flow is convective. Further topics are discussed as they relate the sedimentation tank performance, such as turbulence between opposing flows and shear flow instabilities.

image29.PNG