Abstract:

The Stock Tank Mixing team is required to improve the mixing process for the coagulant and disinfectant in the stock tank. Previous teams have developed the centrifugal pump design, which can mix the following chemicals: aluminum sulfate (alum), polyaluminum chloride (PACl) and calcium hypochlorite (Ca(ClO)3). This team decided to focus on the use of polyaluminum chloride. Due to its chemical properties, it is most likely the future coagulant of most AguaClara plants. The stock tank mixing team plans to design a mixing system that will improve operator ease in use of the mixer, achieve a truly homogeneous mixer, and be scalable to larger plants. The team will also create operator guidelines, and provide the operator with a verification of homogeneity.