Floc App - Spring 2017

Christian Rodriguez, Anthony Verghese, Deniz Yilmazer

Abstract:

Turbidity measurements provide the primary source of performance monitoring at many water treatment plants. Turbidity provides an excellent way to measure overall plant performance, but it fails to provide insight into the specific processes that make up the plant. The earliest reduction in turbidity in an AguaClara plant occurs after the sedimentation tank with a time delay of 30 to 45 minutes. This delay makes feedback control challenging especially when raw water turbidity varies rapidly. The floc size and count app comes in to fill this shortcoming by providing an easyto-use desktop application to measure floc distribution in various parts of the plant. The floc app can measure floc size distribution of the flocculated water to characterize flocculation efficiency. Flocculation residence time is expected to be less than 5 minutes in the next generation of AguaClara plants and this will significantly reduce the feedback time to provide guidance for setting the plant coagulant dose.

flocapp.PNG